Recommendations are provided by manufacturers see application guides. Instrument current voltage transformers part 1 photo credit. It can be designed to step up or step down voltages and works on the magnetic induction principle. A transformer has no moving parts and is a completely.
Current transformers can be mounted on the low voltage or high voltage leads of a power transformer. Figure 1 works well for most instrument transformers. When current flow exceeds that rating, the metering core will become saturated, thereby limiting the amount of current level within the device. A potential transformer is a conventional transformer having primary and secondary windings. Current and voltage transformers provide the interface between the power system high voltage plant primary plant and the protection, control and metering equipment secondary plant. This protects connected metering devices from overloading in the presence of fault level current flows. Voltage transformers are together with current transformers known as instrument transformers. Power transmission and distribution author page 242 200708. Line carrier plc devices that are used for communication over the high voltage transmission circuits. If the losses in the network are neglected, equation.
Current, voltage and combined transformers, oilpaper or gas insulated up to 800 kv. Cts provide isolation from the high voltage primary, permit. This chapter describes the properties of current transformers cts and voltage transformers vts, and how to specify them for particular applications. To transform currents or voltages from high value to a value that can be easily handled by protection relays and instruments. Current and voltage instrument transformers technical and.
Amran instrument transformers is a leading manufacturer of low voltage and medium voltage instrument transformers current and voltage transformers with multiple manufacturing plants in usa and india. It buffers the meter from experiencing excessive torques that might be. A capacitor voltage transformer cvt or ccvt, is a transformer used in power systems to step down extra high voltage signals and provide a low voltage signal, for metering or operating a protective relay. High voltage current transformer january 19, 2016 page. Voltage transformer which is also called as a potential transformer. Pdf virtual instrument for testing of current and voltage. Current voltage transformers split core current transformers rogowski coil power transformers high frequency transformers common mode chokes protection relays reactors intelligent electric power meter. Hence current transformers are used to supply those devices with currents of magnitude proportional to those of power. What is a voltage transformer and a current transformer. Current transformers could be attached to the lower voltage or even high voltage prospects of a power transformer. A transformer is an electrical apparatus designed to convert alternating current from one voltage to another.
Instrument transformers are used for measurement and protective application, together with equipment such as meters and relays. Basics, maintenance, and diagnostics vii contents continued page 4. Their role in electrical systems is of primary importance as they are a means of stepping down the current or voltage of a system to measurable values, such as 5a or 1a in the case of a current transformers or 110v or 100v in the case of a voltage transformer. It employed in electrical energy power system for stepping down the voltage of the system to some protected value which is often provided to low rating meter. In case of bus ct, there must be always connected ct shielding to the primary bar. The basics of current transformers nk technologies. Maximum allowed torques for screw connections of current transformers maximum allowed torque for screw connection of voltage transformer is 20 nm. Amrans product portfolio includes standard products as well as numerous custom products specifically designed and developed for oem specific. Nov 15, 2019 the measuring devices cannot be directly connected to the high magnitude supplies.
The ratio of the primary to the secondary, the ratio of the input to the output, and the turns ratio of any given transformer will be the same as its voltage ratio. The output of a constantvoltage transformer is essentially a square wave, which is desirable for rectifier output applications while, also. Medium voltage products current and voltage instrument. The earlier sections of this chapter deal with current transformers, including primary injection techniques, and the later sections with voltage transformers. Current transformer white paper the basics of current transformers ratio the ct ratio is the ratio of primary current input to secondary current output at full load. Mathematical models for current, voltage, and coupling capacitor voltage transformers working group c5 of the systems protection subcommittee of the ieee power system relaying committee, demetrios a.
The specific performance characteristics of current and voltage instrument transformers are easily determined from the equivalent circuit. To transform currents or voltages from a usually high value to a value easy to handle for relays and instruments. A transformer changes the voltage level or current level on its input winding to another value on its output winding using a magnetic field. Current transformers reduce high voltage currents to a much lower value and provide a convenient way of safely monitoring the actual electrical current flowing in an ac transmission line using a standard ammeter. Current and voltage transformers are required to transform high currents and voltages into more manageable quantities for measurement, protection, and control. Current transformers reduce high voltage currents to a much lower value and provide a convenient way of safely monitoring the. In any electrical system power system, instrument transformers forms part of main components in metering reading instruments, recording instruments, tariff systems, protection and control system applications. Current transformers cts are instrument transformers that are used to supply a reduced value of current to me ters, protective relays, and other instruments. Loading considerations when paralleling transformers.
Arteche offers a wide range that covers all our customers needs. To insulate the metering circuit from the primary high voltage system. Oct 08, 2016 applications of current transformers current transformers are used extensively for measuring current and monitoring the operation of the power grid. Upt primary voltage ust secondary voltage 1 fault inception 2 aperiodic damping of ust 3 periodic damping of ust time ts in ms ratio classes 3pt1 6pt1 3pt2 6pt2 3pt3 6pt3 10. A current transformer also isolates the measuring instruments from high voltage circuits. The instrument transformers like voltage transformer and current transformer are used for connecting the electrical instruments to the measuring instruments. Current transformer basics and the current transformer. The standard that describes voltage transformers in details is iec 186. Virtual instrument for testing of current and voltage transformers article pdf available in conference record ieee instrumentation and measurement technology conference january 2 with 140 reads. Voltage transformers 121 the gross input in watts from a power circuit to a capacitance potentialdevice network is. Abaout ttt eocneccbivbycosnabcyaecntecagcnl mr transformers are used to accurately measure high alternating primary currents, converting the primary current into a.
Current transformers can be used to keep an eye on dangerously higher currents or currents at risky high voltages, so excellent proper care should be ingested the structure and use of cts during these scenarios. Jun, 2019 current transformers could be attached to the lower voltage or even high voltage prospects of a power transformer. Loading considerations when paralleling transformers it can be seen by using equations 1 and 2 below, that if the percent impedances in each transformer are the same, as shown in figure 1, that there will be equal current division and load sharing on each transformer. Our low voltage halogen transformers are simply the best, but other than that theres nothing simple about them. Instrument transformer basic technical information and. K tf values required in practice depend on relay type and design. The function of a transformer primaryside protective device is, in general, to provide system protection as. Current and voltage instrument transformers applicaton guide for current transformers, the value of the. Lowvoltage halogen electronic transformers current. A transformer consists of two electrically isolated coils and operates on faradays principal of mutual induction, in which an emf is induced.
Cts current transformers pts potential transformers. Mathematical models for current, voltage, and coupling. Current or voltage instrument transformers are necessary to isolate the protection, control and measurement equipment from the high voltages of a power system, and for supplying the equipment with the appropriate values of current and voltage generally these are 1 or 5 a for the current coils, and 120 v for the voltage coils. Current transformers, standard for transient performance. Instrument transformers convert signal levels from dangerous high voltage or inconvenient high current, or current at high voltage to levels appropriate for metering.
The constantvoltage transformer cvt has a wide application, particularly where reliability and inherent regulating ability against line voltage changes are of prime importance. At 5% rated current through 100%, the current transformer must maintain 0. The principal of operation of a basic current transformer is slightly different from that of an ordinary voltage transformer. In addition, embedded technology makes the transformers runs cool with. These transformers reduce the voltage and current from high value to the low value which can be measured by conventional instruments. Tziouvaras, chairman, peter mclaren, vice chairman, george alexander, douglas dawson. In its most basic form, the device consists of three parts. The actual number of turns of wire on any winding is generally not important. Voltage transformers are in most situations connected between phase and ground. Instrument transformers are high accuracy class electrical devices used to isolate or transform voltage or current levels. The standard that describes voltage transformers in details is iec. Instrument transformers convert the currents and voltages of the h. The most common usage of instrument transformers is to operate instruments or metering from high voltage or high current circuits, safely isolating secondary control circuity from the high voltages or currents.